Smart dehumidifier
SG.CSL.600S
Review SG.CSL.600S by cabinet volume, humidity condition, dehumidifying capacity, drain path, power supply, alarm or RS485 needs before sending a humidity-control quote request.
Match humidity control to the cabinet
Share cabinet volume, humidity condition, water-mark photos, drain route, power supply and monitoring needs before quote.
Key specifications
Use these product details to compare models, then request the latest datasheet, drawing, certificate coverage and availability before ordering.
Product details
Request before ordering
SG.CSL.600S model sheet and drawing references
Model inquiry sheet for preparing the request. Ask for current documents before order.
Model sheet
| Power supply | AC/DC80V-275V or DC12-48V optional |
|---|---|
| Power / capacity | 60W / 450+-10% ml/day at 35C RH90% |
| Operating range | -25C to +65C; operating humidity <=95%RH |
| Material | ABS plastic |
| Body size | 100x72x170mm |
| Mounting | bracket mounting or rail mounting |
| Wiring / options | RS485 optional; sound/light alarm optional; sensor internal with optional external sensor; 2m soft hose drain |
| Related options | external heater optional; external fan optional on selected model; drain hose; RS485; alarm module |
Drawing references
Use these drawing references to prepare the request; ask for current installation, drain and option documents before ordering.
Before quotation
- Confirm cabinet volume, sealing condition, humidity load and drain path before sizing.
- Confirm external heater, fan, alarm, RS485 and sensor options before quotation.
- Request current installation, drain and maintenance instructions before ordering.
Best fit
- Use this path when cabinet humidity, temperature swing or visible water marks make simple ventilation risky.
- Check cabinet volume, drain route, available mounting space and service access before choosing the size.
- Add alarm, RS485, external sensor, heater or fan requirements if the cabinet needs monitoring or linked control.
Send with inquiry
SG.CSL.600S humidity-control check
| Power | 60W |
|---|---|
| Moisture removal | 450+-10% ml/day at 35C RH90% |
| Cabinet space | 1-2.5 m3 |
| Operating temperature | -25C to +65C |
| Operating humidity | <=95%RH |
| Measurement range | 0%RH-99%RH |
| Measurement accuracy | +/-5%RH |
| Working threshold | 65%RH default |
| Threshold adjustment | working threshold adjustable |
| Alarm option | sound/light alarm optional |
| Remote communication | RS485 optional |
| Sensor position | internal, optional external |
| Drain method | soft hose drain, length 2m |
| Installation | bracket mounting or rail mounting |
| External heater | 50-500W optional |
| External fan | 50-500W optional |
| Power supply | AC/DC80V-275V or DC12-48V optional |
| Size | 100x72x170mm |
| Housing | ABS plastic |
Model details
| Product family | Smart Dehumidifiers |
|---|---|
| Product type | dehumidifier |
| Voltage | AC/DC80V-275V or DC12-48V optional |
| Power | 60W |
| Airflow | 450+-10% ml/day at 35C RH90% |
| Dimensions | 100x72x170mm |
| Mounting | bracket mounting or rail mounting |
| Wiring | RS485 optional; sound/light alarm optional; sensor internal with optional external sensor; 2m soft hose drain |
Quote details
If this is a replacement inquiry, include old label photos, front grille size, cutout size, voltage and required fit tolerance.
SG.CSL.600S cabinet dehumidifier RFQ
Use this section to organize replacement details, quote requirements and document requests before contacting the supplier.
- High-humidity cabinet projects where active dehumidification is being considered instead of only ventilation or heating.
- Outdoor or semi-outdoor enclosure inquiries that need humidity condition, drain options and service access reviewed.
- OEM requests that need RS485, alarm, external sensor or heater/fan options confirmed before quoting.
Replacement and RFQ inputs
These inputs help separate a fit-check, a new cabinet design, a distributor quote and a document request.
Details to ask before quote
- Confirm option availability for external heater, fan, alarm, RS485 and sensor.
- Request installation, drain and maintenance instructions.
- Ask for sizing rule by cabinet volume, humidity load and temperature condition.
Can SG.CSL.600S be sized by cabinet volume alone?
No. Sealing, humidity load, temperature swing, drain path and service access also matter.
What should be included for outdoor cabinets?
State outdoor exposure, condensation history, cabinet volume, drain path and any alarm or remote monitoring need.
How should performance be checked?
Use this page to shortlist the model, then send cabinet conditions so the supplier can recommend sizing and operating settings.
Related model request pages
Compare nearby models in the same product family before sending drawings, labels or document requests.
SG.CSL.200L
Smart Dehumidifiers product page for comparing voltage, size, airflow and quotation details.
SG.CSL.450L
Smart Dehumidifiers product page for comparing voltage, size, airflow and quotation details.
SG.CSL.600L
Smart Dehumidifiers product page for comparing voltage, size, airflow and quotation details.
Documents to request before ordering
- Current model name and export status.
- Datasheet, dimension drawing, wiring or cutout drawing where relevant.
- Certificate coverage by model or approved series coverage.
- MOQ, sample availability, lead time and private-label limits.