Smart dehumidifier
SG.CSL.200L
Review SG.CSL.200L by cabinet volume, humidity condition, dehumidifying capacity, drain path, power supply, alarm or RS485 needs before sending a humidity-control quote request.
Match humidity control to the cabinet
Share cabinet volume, humidity condition, water-mark photos, drain route, power supply and monitoring needs before quote.
Key specifications
Use these product details to compare models, then request the latest datasheet, drawing, certificate coverage and availability before ordering.
Product details
Request before ordering
SG.CSL.200L model sheet and drawing references
Model inquiry sheet for preparing the request. Ask for current documents before order.
Model sheet
| Power supply | AC/DC80V-275V or DC12-48V optional |
|---|---|
| Power / capacity | 20W / 150+-10% ml/day at 35C RH90% |
| Operating range | -25C to +65C; operating humidity <=95%RH |
| Material | aluminum alloy |
| Body size | 85x55x105mm |
| Mounting | bracket mounting or rail mounting |
| Wiring / options | RS485 optional; sound/light alarm optional; sensor internal with optional external sensor; 2m soft hose drain |
| Related options | external heater optional; external fan optional on selected model; drain hose; RS485; alarm module |
Drawing references
Use these drawing references to prepare the request; ask for current installation, drain and option documents before ordering.
Before quotation
- Confirm cabinet volume, sealing condition, humidity load and drain path before sizing.
- Confirm alarm, RS485, sensor and accessory options before quotation.
- Request current installation, drain and maintenance instructions before ordering.
- Confirm table dimensions against the current drawing before using this model for mounting work.
Best fit
- Use this path when cabinet humidity, temperature swing or visible water marks make simple ventilation risky.
- Check cabinet volume, drain route, available mounting space and service access before choosing the size.
- Add alarm, RS485, external sensor, heater or fan requirements if the cabinet needs monitoring or linked control.
Send with inquiry
SG.CSL.200L humidity-control check
| Power | 20W |
|---|---|
| Moisture removal | 150+-10% ml/day at 35C RH90% |
| Cabinet space | 0.5-1.2 m3 |
| Operating temperature | -25C to +65C |
| Operating humidity | <=95%RH |
| Measurement range | 0%RH-99%RH |
| Measurement accuracy | +/-5%RH |
| Working threshold | 65%RH default |
| Threshold adjustment | working threshold adjustable |
| Alarm option | sound/light alarm optional |
| Remote communication | RS485 optional |
| Sensor position | internal, optional external |
| Drain method | soft hose drain, length 2m |
| Installation | bracket mounting or rail mounting |
| Power supply | AC/DC80V-275V or DC12-48V optional |
| Size | 85x55x105mm |
| Housing | aluminum alloy |
Model details
| Product family | Smart Dehumidifiers |
|---|---|
| Product type | dehumidifier |
| Voltage | AC/DC80V-275V or DC12-48V optional |
| Power | 20W |
| Airflow | 150+-10% ml/day at 35C RH90% |
| Dimensions | 85x55x105mm |
| Mounting | bracket mounting or rail mounting |
| Wiring | RS485 optional; sound/light alarm optional; sensor internal with optional external sensor; 2m soft hose drain |
Quote details
If this is a replacement inquiry, include old label photos, front grille size, cutout size, voltage and required fit tolerance.
SG.CSL.200L cabinet dehumidifier quote details
Use this section to organize replacement details, quote requirements and document requests before contacting the supplier.
- High-humidity enclosure projects where ventilation or heating alone may not be enough.
- Outdoor or semi-outdoor cabinets where drain options, service access and humidity alarm options matter.
- OEM requests that need power supply, RS485, alarm, external sensor or heater/fan options confirmed.
Replacement and RFQ inputs
These inputs help separate a fit-check, a new cabinet design, a distributor quote and a document request.
Details to ask before quote
- Confirm power-supply option and accessory availability.
- Request installation, drain and maintenance instructions.
- Ask for sizing rule by cabinet volume, humidity load and temperature condition.
Can this be sized by volume alone?
No. Sealing, humidity load, temperature swing, drain path and maintenance access also matter.
What should outdoor cabinet requests include?
Outdoor exposure, condensation history, cabinet volume, drain path and monitoring needs.
Can this guarantee dry cabinets?
No. It supports a humidity-control options, but final performance depends on cabinet and installation conditions.
Related model request pages
Compare nearby models in the same product family before sending drawings, labels or document requests.
SG.CSL.600S
Smart Dehumidifiers product page for comparing voltage, size, airflow and quotation details.
SG.CSL.450L
Smart Dehumidifiers product page for comparing voltage, size, airflow and quotation details.
SG.CSL.600L
Smart Dehumidifiers product page for comparing voltage, size, airflow and quotation details.
Documents to request before ordering
- Current model name and export status.
- Datasheet, dimension drawing, wiring or cutout drawing where relevant.
- Certificate coverage by model or approved series coverage.
- MOQ, sample availability, lead time and private-label limits.