Cabinet air conditioner
QA3200
Review QA3200 by heat load, ambient temperature, target cabinet temperature, power supply, cutout and target market before sending a cabinet air conditioner quote request.
Match cooling capacity to the cabinet
Share cabinet heat load, ambient range, target internal temperature, mounting position, cutout drawing, power supply and destination market.
Key specifications
Use these product details to compare models, then request the latest datasheet, drawing, certificate coverage and availability before ordering.
Product details
Request before ordering
QA3200 model sheet and drawing references
Model inquiry sheet for preparing the request. Ask for current documents before order.
Model sheet
| Power supply / frequency | Request power-supply details / 50Hz |
|---|---|
| Cooling / rated power | 3200W cooling capacity; 1615W rated power / 7.4A |
| Airflow | 610 m3/h internal circulation; 1150 m3/h external circulation |
| IP rating | IP34 internal circulation; IP33 external circulation |
| Operating range | recommended cabinet set range 25C-38C; factory set 30C; ambient use -5C to +43C |
| Unit size | 436x1113x270mm |
| Cutout | cutout drawing; detailed opening dimensions require CAD/datasheet or review |
| Mounting | side/panel mount per cutout drawing |
| Connection | power cable; external cable length 2m |
| Related items | digital display temperature controller; enclosure thermal management |
Drawing references
Use these drawing references to prepare the request; ask for the current cutout drawing and electrical documents before machining or ordering.
Before quotation
- Confirm power-supply wording and current model status before quotation.
- Request current cutout drawing, datasheet, wiring detail and electrical safety documents.
- Confirm refrigerant and target-market suitability before offering or publishing stronger wording.
Best fit
- Use this path when the cabinet heat load, ambient range and target internal temperature are available.
- For sealed cabinets or high heat-load equipment, include cabinet drawings and installation position.
- For replacement, include the old unit label, cutout photos and destination market before quotation.
Send with inquiry
QA3200 project check
| Cooling capacity | 3200W |
|---|---|
| Power supply | Request power-supply details |
| Rated current / power | 7.4A / 1615W |
| Internal / external airflow | 610 m3/h / 1150 m3/h |
| Cabinet temperature | 25C-38C; factory set 30C |
| Ambient range | -5C to +43C |
| Refrigerant | R22 |
| Mounting / cutout | side/panel mount per cutout drawing |
Model details
| Product family | Cabinet Air Conditioners |
|---|---|
| Product type | cabinet air conditioning |
| Voltage | Request power-supply details |
| Frequency | 50Hz |
| Power | 3200W cooling capacity; 1615W rated power |
| Current | 7.4A |
| Airflow | 610 m3/h internal circulation; 1150 m3/h external circulation |
| IP rating | IP34 internal circulation; IP33 external circulation |
| Dimensions | 436x1113x270mm |
| Cutout size | cutout drawing; detailed opening dimensions require CAD/datasheet or review |
| Mounting | side/panel mount per cutout drawing |
| Wiring | power cable; external cable length 2m |
Quote details
If this is a replacement inquiry, include old label photos, front grille size, cutout size, voltage and required fit tolerance.
QA3200 cabinet air conditioner RFQ
Use this section to organize replacement details, quote requirements and document requests before contacting the supplier.
- Higher heat-load cabinet cooling projects where a buyer needs a model options but must still confirm heat load and ambient conditions.
- Replacement or upgrade requests where cutout, refrigerant suitability and market restrictions must be reviewed before quotation.
- Project RFQs needing cooling capacity, airflow, power supply and required documents separated from final sizing.
Replacement and RFQ inputs
These inputs help separate a fit-check, a new cabinet design, a distributor quote and a document request.
Details to ask before quote
- Confirm QA3200 power-supply wording and current model status.
- Request cutout drawing, datasheet and electrical safety documents.
- Confirm R22 market suitability before offering or publishing stronger wording.
Can QA3200 be selected from cooling capacity alone?
No. Heat load, ambient temperature, target cabinet temperature, sealing and installation must be reviewed.
Why is refrigerant mentioned in the RFQ?
The product listing references R22, so target-market suitability must be checked before quotation.
What files are most important?
Cutout drawing, datasheet, wiring details and market-specific compliance documents.
Related model request pages
Compare nearby models in the same product family before sending drawings, labels or document requests.
QA300
Cabinet Air Conditioners product page for comparing voltage, size, airflow and quotation details.
QA320-1225
Cabinet Air Conditioners product page for comparing voltage, size, airflow and quotation details.
QA450
Cabinet Air Conditioners product page for comparing voltage, size, airflow and quotation details.
QA500
Cabinet Air Conditioners product page for comparing voltage, size, airflow and quotation details.
QA600
Cabinet Air Conditioners product page for comparing voltage, size, airflow and quotation details.
Documents to request before ordering
- Current model name and export status.
- Datasheet, dimension drawing, wiring or cutout drawing where relevant.
- Certificate coverage by model or approved series coverage.
- MOQ, sample availability, lead time and private-label limits.