Cabinet air conditioner

QA300

Review QA300 by heat load, ambient temperature, target cabinet temperature, power supply, cutout and target market before sending a cabinet air conditioner quote request.

Send model, quantity, cabinet conditions and required documents before ordering.
Cabinet Air Conditioners product reference

Match cooling capacity to the cabinet

Share cabinet heat load, ambient range, target internal temperature, mounting position, cutout drawing, power supply and destination market.

Key specifications

Use these product details to compare models, then request the latest datasheet, drawing, certificate coverage and availability before ordering.

AC 220V/50Hz / 50Hz Voltage / freq
300W cooling capacity; 266W rated power / 1.46A Power / current
150 m3/h internal circulation; 230 m3/h external circulation Airflow / pressure
286x460x175mm / cutout drawing; detailed opening dimensions require CAD/datasheet or review Size / cutout
side/panel mount per cutout drawing / reserved terminal Mounting / wiring

Product details

AC 220V/50Hz50Hz300W cooling capacity; 266W rated power150 m3/h internal circulation; 230 m3/h external circulationIP34 internal circulation; IP33 external circulation286x460x175mmcutout drawing; detailed opening dimensions require CAD/datasheet or reviewside/panel mount per cutout drawing

Request before ordering

required certificate or market documentssample quantity and order quantity

QA300 model sheet and drawing references

Model inquiry sheet for preparing the request. Ask for current documents before order.

Model sheet

Power supply / frequencyAC 220V/50Hz / 50Hz
Cooling / rated power300W cooling capacity; 266W rated power / 1.46A
Airflow150 m3/h internal circulation; 230 m3/h external circulation
IP ratingIP34 internal circulation; IP33 external circulation
Operating rangerecommended cabinet set range 25C-38C; factory set 32C; ambient use -5C to +45C
Unit size286x460x175mm
Cutoutcutout drawing; detailed opening dimensions require CAD/datasheet or review
Mountingside/panel mount per cutout drawing
Connectionreserved terminal
Related itemsdigital display temperature controller; enclosure thermal management

Drawing references

QA300 cabinet air conditioner product view reference
Product view reference
QA300 cutout drawing reference
Cutout drawing reference
QA300 exterior dimensions drawing reference
Exterior dimensions reference
Unit size 286 x 460 x 175 mm
Cutout Request current cutout drawing before panel machining
Exterior 286 x 460 x 175 mm
Mounting Side/panel mount per cutout drawing

Use these drawing references to prepare the request; ask for the current cutout drawing and electrical documents before machining or ordering.

Before quotation

  • Confirm model status and power-supply wording before quotation.
  • Request current cutout drawing, datasheet and electrical safety documents.
  • Confirm refrigerant and target-market suitability before offering or publishing stronger wording.

Best fit

  • Use this path when the cabinet heat load, ambient range and target internal temperature are available.
  • For sealed cabinets or high heat-load equipment, include cabinet drawings and installation position.
  • For replacement, include the old unit label, cutout photos and destination market before quotation.

Send with inquiry

heat loadambient temptarget tempcabinet sizecutout drawingtarget market

QA300 project check

Cooling capacity300W
Power supplyAC 220V/50Hz
Rated current / power1.46A / 266W
Internal / external airflow150 m3/h / 230 m3/h
Cabinet temperature25C-38C; factory set 32C
Ambient range-5C to +45C
RefrigerantR134a
Mounting / cutoutside/panel mount per cutout drawing

Model details

Product familyCabinet Air Conditioners
Product typecabinet air conditioning
VoltageAC 220V/50Hz
Frequency50Hz
Power300W cooling capacity; 266W rated power
Current1.46A
Airflow150 m3/h internal circulation; 230 m3/h external circulation
IP ratingIP34 internal circulation; IP33 external circulation
Dimensions286x460x175mm
Cutout sizecutout drawing; detailed opening dimensions require CAD/datasheet or review
Mountingside/panel mount per cutout drawing
Wiringreserved terminal

Quote details

exact model and quantitycurrent datasheet and drawing needrequired certificate or market documentstarget market and applicationold model photo and replacement constraints

If this is a replacement inquiry, include old label photos, front grille size, cutout size, voltage and required fit tolerance.

QA300 cabinet air conditioner quote details

Use this section to organize replacement details, quote requirements and document requests before contacting the supplier.

  • Cabinet cooling projects where heat load, ambient temperature and target internal temperature must be reviewed before model selection.
  • Replacement or retrofit requests where cutout, mounting, refrigerant and power supply details can block quotation.
  • Project RFQs that need cooling capacity, airflow and electrical documents separated from final sizing.

Replacement and RFQ inputs

cabinet heat loadcabinet dimensionsambient and target temperatureexisting cutout or mounting photostarget market and document needs

These inputs help separate a fit-check, a new cabinet design, a distributor quote and a document request.

Details to ask before quote

  • Confirm model status, power-supply wording and target market suitability.
  • Request cutout drawing, datasheet, wiring detail and electrical safety documents.
  • Confirm refrigerant and certificate coverage before offering or public copy.

Can cooling capacity alone choose the model?

No. Heat load, ambient temperature, target cabinet temperature, sealing and installation must be reviewed.

What files help replacement most?

Old unit label, cutout drawing, cabinet photos and target market requirements.

Can this page be used as the final datasheet?

No. Request the latest datasheet and market documents before ordering.

Related model request pages

Documents to request before ordering

  • Current model name and export status.
  • Datasheet, dimension drawing, wiring or cutout drawing where relevant.
  • Certificate coverage by model or approved series coverage.
  • MOQ, sample availability, lead time and private-label limits.