Thermostat and hygrostat

SG.KTO011 (NC)

Review SG.KTO011 (NC) by control type, NO/NC or change-over logic, setting range, switching capacity, terminal count and DIN-rail space before sending a control-device quote request.

Send model, quantity, cabinet conditions and required documents before ordering.
Thermostats & Hygrostats product reference

Match the contact logic to the load

Share the controlled load, NO/NC or change-over need, set range, switching current, terminal photo and DIN-rail space before quote.

Key specifications

Use these product details to compare models, then request the latest datasheet, drawing, certificate coverage and availability before ordering.

TBC Voltage / freq
max switching capacity 25A AC; 10A available Power / current
TBC Airflow / pressure
60x33x43mm Size / cutout
clip for 35mm DIN rail, EN 60715 / 2-pole / terminal connection provided; technical table lists 4-pole terminal common family wording, max clamping torque 0.5Nm; rigid wire 2.5mm2; stranded wire with wire end ferrule 1.5mm2 Mounting / wiring

Product details

max switching capacity 25A AC; 10A availableIP20 / class II60x33x43mmclip for 35mm DIN rail, EN 607152-pole / terminal connection provided; technical table lists 4-pole terminal common family wording, max clamping torque 0.5Nm; rigid wire 2.5mm2; stranded wire with wire end ferrule 1.5mm2

Request before ordering

VDE+UL file number E164102 provided in table; required certificate or market documentssample quantity and order quantity

SG.KTO011 (NC) model sheet and drawing references

Model inquiry sheet for preparing the request. Ask for current documents before order.

Model sheet

Switching capacitymax switching capacity 25A AC; 10A available
IP / classIP20 / class II
Operating range-10C to +55C
Materialplastic according to UL94 V-0, light grey
Body size60x33x43mm
Mountingclip for 35mm DIN rail, EN 60715
Connection2-pole / terminal connection provided; technical table lists 4-pole terminal common family wording, max clamping torque 0.5Nm; rigid wire 2.5mm2; stranded wire with wire end ferrule 1.5mm2
Related loadheater

Drawing references

SG.KTO011 NC thermostat body dimensions drawing reference
Body dimensions reference
SG.KTO011 NC thermostat product views reference
Product views reference
SG.KTO011 NC thermostat connection diagram reference
Connection diagram reference
Body 60 x 33 x 43 mm
Contact NC heater-control path
Switch difference 7K +/-4K
Rail 35 mm DIN rail

Use these drawing references to prepare the request; ask for the current wiring diagram and contact-load documents before ordering.

Before quotation

  • Confirm controlled load, voltage, current and required NC contact logic before quotation.
  • Request current wiring diagram and terminal specification before panel wiring.
  • Confirm certificate scope before using compliance wording.

Best fit

  • Use this path when cabinet temperature should switch a heater, fan, cooling load or signal circuit.
  • Check contact logic before pairing the device with heater.
  • For replacement, send the old label, terminal photo, setpoint range and controlled load before quotation.

Send with inquiry

controlled loadNO / NC / change-overvoltageswitching currentset rangewiring photo

SG.KTO011 (NC) control and wiring check

Device typemechanical thermostat
Primary controltemperature
Contact logicnormally closed contact closes below set temperature for heater control
Setting rangesingle adjustable temperature dial available, approx 0C-60C scale
Switch difference7K +/-4K
Reaction timemechanical sensing note says approx 10 minutes per degree
Switching capacity25A AC, 10A available
Connection2-pole product drawing; table family wording mentions 4-pole terminal; max clamping torque 0.5Nm
Mountingclip for 35mm DIN rail, EN 60715
Size60x33x43mm
ProtectionIP20 / class II
Operating temperature-10C to +55C
Typical loadsheater

Model details

Product familyThermostats & Hygrostats
Product typethermostat
Powermax switching capacity 25A AC; 10A available
IP ratingIP20 / class II
Dimensions60x33x43mm
Mountingclip for 35mm DIN rail, EN 60715
Wiring2-pole / terminal connection provided; technical table lists 4-pole terminal common family wording, max clamping torque 0.5Nm; rigid wire 2.5mm2; stranded wire with wire end ferrule 1.5mm2

Quote details

exact model and quantitycurrent datasheet and drawing needrequired certificate or market documentstarget market and applicationold model photo and replacement constraints

If this is a replacement inquiry, include old label photos, front grille size, cutout size, voltage and required fit tolerance.

SG.KTO011 NC thermostat heater control request

Use this section to organize replacement details, quote requirements and document requests before contacting the supplier.

  • Heater-control inquiries where a normally closed thermostat is needed to switch a cabinet heater below set temperature.
  • Replacement requests where terminal count, wiring diagram and DIN rail mounting must be checked.
  • OEM control-panel builds pairing heaters, fans and thermostat logic in one cabinet environment.

Replacement and RFQ inputs

controlled load and currentNO/NC contact requirementset temperature rangewiring photo or old thermostat label

These inputs help separate a fit-check, a new cabinet design, a distributor quote and a document request.

Details to ask before quote

  • Confirm terminal count and wiring diagram for SG.KTO011.
  • Request switching capacity and service-life required documents.
  • Confirm certificate coverage before compliance wording.

What does NC mean for this inquiry?

NC is typically used for heater control, closing below set temperature; confirm the wiring diagram before use.

Can SG.KTO011 control a fan?

Fan control usually uses a normally open thermostat path; confirm the load and contact logic.

What is the safest RFQ wording?

State controlled device, current, voltage, set range and required contact logic instead of assuming the circuit.

Related model request pages

Documents to request before ordering

  • Current model name and export status.
  • Datasheet, dimension drawing, wiring or cutout drawing where relevant.
  • Certificate coverage by model or approved series coverage.
  • MOQ, sample availability, lead time and private-label limits.