Cabinet heater

SG.CR018

Compare SG.CR018 by heating output, voltage, mounting and cabinet use case before sending a heater quote request.

Send model, quantity, cabinet conditions and required documents before ordering.
Cabinet Heaters product reference

Match the heater to the cabinet

Share cabinet size, minimum ambient temperature, target internal temperature, voltage, mounting space and control method for a clearer heater reply.

Key specifications

Use these product details to compare models, then request the latest datasheet, drawing, certificate coverage and availability before ordering.

120-240V AC Voltage / freq
10W; 20W (page headline also mentions 30W and custom variants) / 10W max 1.0A; 20W max 2.5A Power / current
TBC Airflow / pressure
100x35x18mm body drawing; 100mm length in table Size / cutout
screw fixing / 2 x AWG18 multi-strand lead Mounting / wiring

Product details

120-240V AC10W; 20W (page headline also mentions 30W and custom variants)IP32 / class II double insulated100x35x18mm body drawing; 100mm length in tablescrew fixing2 x AWG18 multi-strand lead

Request before ordering

sample quantity and order quantity

SG.CR018 model sheet and drawing references

Model inquiry sheet for preparing the request. Ask for current documents before order.

Model sheet

Voltage120-240V AC
Power / current10W; 20W (page headline also mentions 30W and custom variants) / 10W max 1.0A; 20W max 2.5A
IP / classIP32 / class II double insulated
Operating range-40C to +65C
Materialanodised aluminum heater body; PTC resistor self-regulating and temperature limiting
Body size100x35x18mm body drawing; 100mm length in table
Mountingscrew fixing
Wiring2 x AWG18 multi-strand lead
Related controlthermostat SG.KTO 011

Drawing references

SG.CR018 heater body dimensions drawing reference
Body dimensions reference
SG.CR018 wiring reference
Wiring reference
SG.CR018 heater strip reference
Heater strip reference
Body 100 x 35 x 18 mm
Length 100 mm
Power options 10 W / 20 W
Connection 2 x AWG18 leads

Use these drawing references to prepare the request; ask for the current heater drawing and wiring detail before ordering.

Before quotation

  • Confirm whether the required SKU is 10 W, 20 W or another custom wattage.
  • Match cabinet size, minimum ambient and control method before selecting heater wattage.
  • Request current drawing, wiring detail and certificate scope before ordering.

Best fit

  • Use small PTC heaters for compact cabinets and anti-condensation support.
  • Use higher output or fan-assisted heaters when warm-up speed matters.
  • Add thermostat or hygrostat control when cabinet temperature or humidity should switch automatically.

Send with inquiry

cabinet sizeminimum ambienttarget temperaturevoltagemounting spacecontrol method

SG.CR018 heater variants

VariantVoltageHeating outputAir movementSize
10W 120-240V AC 10W Natural convection 100mm length; body drawing 100x35x18mm
20W 120-240V AC 20W Natural convection 100mm length; body drawing 100x35x18mm

Model details

Product familyCabinet Heaters
Product typeheater
Voltage120-240V AC
Power10W; 20W (page headline also mentions 30W and custom variants)
Current10W max 1.0A; 20W max 2.5A
IP ratingIP32 / class II double insulated
Dimensions100x35x18mm body drawing; 100mm length in table
Mountingscrew fixing
Wiring2 x AWG18 multi-strand lead

Quote details

exact model and quantitycurrent datasheet and drawing needrequired certificate or market documentstarget market and applicationold model photo and replacement constraints

If this is a replacement inquiry, include old label photos, front grille size, cutout size, voltage and required fit tolerance.

SG.CR018 cabinet heater inquiry

Use this section to organize replacement details, quote requirements and document requests before contacting the supplier.

  • Anti-condensation or low-temperature startup inquiries where heater wattage must match cabinet size and installation condition.
  • Replacement requests for compact enclosure heaters where mounting and wiring details must be checked.
  • Panel builder standardization requests pairing heater, thermostat and cabinet environment data.

Replacement and RFQ inputs

cabinet dimensions and installation positionminimum ambient and target internal temperaturevoltage and wiring constraintsthermostat or hygrostat control requirement

These inputs help separate a fit-check, a new cabinet design, a distributor quote and a document request.

Details to ask before quote

  • Confirm SG.CR018 wattage range and any headline/table mismatch.
  • Request current heater drawing and wiring detail.
  • Ask whether anti-condensation sizing uses the recorded formula or supplier-confirmed examples.

Can heater wattage be chosen from model name alone?

No. Cabinet surface area, ambient temperature, target temperature and installation position matter.

Should a thermostat be included?

Often yes, but the RFQ should state whether the heater is for startup, anti-condensation or both.

What should not be promised yet?

Do not guarantee anti-condensation performance until cabinet conditions and control strategy are reviewed.

Related model request pages

Documents to request before ordering

  • Current model name and export status.
  • Datasheet, dimension drawing, wiring or cutout drawing where relevant.
  • Certificate coverage by model or approved series coverage.
  • MOQ, sample availability, lead time and private-label limits.