Product family

Vortex Fans

Cabinet fan options for airflow, pressure, voltage, frame size, mounting and replacement review.

Compare frame size, voltage, airflow, pressure condition, noise, wiring and mounting before sending a fan quote request.
Vortex Fans product reference

Choose by airflow path and mounting condition

Start with frame size, voltage, airflow target, pressure condition, noise limit, mounting space and wiring style.

Impeller range phi133, phi175, phi180

Use this range to shortlist models before sending cabinet conditions, quantity and document needs.

Voltage 230V, 220V, 3-phase 380V

Use this range to shortlist models before sending cabinet conditions, quantity and document needs.

Airflow 50Hz: 238 m3/h; 60Hz: 277 m3/h, 50Hz: 465 m3/h; 60Hz: 540 m3/h, 50Hz: 455 m3/h; 60Hz: 520 m3/h

Use this range to shortlist models before sending cabinet conditions, quantity and document needs.

Noise 50Hz: 55 dB(A); 60Hz: 58 dB(A), 50Hz: 63.5 dB(A); 60Hz: 71.5 dB(A), 50Hz: 62.6 dB(A); 60Hz: 71.5 dB(A)

Use this range to shortlist models before sending cabinet conditions, quantity and document needs.

Pressure-sensitive airflow

Use vortex fans when the air path has resistance and free-air axial fan numbers are not enough.

pressureresistanceair path

Suffix and voltage

Share exact suffix, voltage, frequency and mounting position before quotation.

suffixvoltagefrequency

Performance condition

Compare airflow with the stated pressure condition and required operating temperature.

conditiontemperaturecurve

Vortex fan model comparison

ModelImpellerVoltageAirflowSpeedNoise
SG133FLW-23phi133230V50Hz: 238 m3/h; 60Hz: 277 m3/h50Hz: 2700 rpm; 60Hz: 3135 rpm50Hz: 55 dB(A); 60Hz: 58 dB(A)
SG175FLW-23phi175220V50Hz: 465 m3/h; 60Hz: 540 m3/h50Hz: 2590 rpm; 60Hz: 2990 rpm50Hz: 63.5 dB(A); 60Hz: 71.5 dB(A)
SG180FLW-23phi180220V50Hz: 455 m3/h; 60Hz: 520 m3/h50Hz: 2560 rpm; 60Hz: 2880 rpm50Hz: 62.6 dB(A); 60Hz: 71.5 dB(A)
SG190FLW-23phi190220V50Hz: 560 m3/h; 60Hz: 630 m3/h50Hz: 2540 rpm; 60Hz: 2850 rpm50Hz: 64 dB(A); 60Hz: 72 dB(A)
SG190FLW-23Tphi190220V50Hz: 620 m3/h; 60Hz: 745 m3/h50Hz: 2470 rpm; 60Hz: 2680 rpm50Hz: 64 dB(A); 60Hz: 72 dB(A)
SG220FLW-23phi220220V50Hz: 970 m3/h; 60Hz: 1075 m3/h50Hz: 2560 rpm; 60Hz: 2770 rpm50Hz: 70 dB(A); 60Hz: 73.5 dB(A)
SG225FLW-23phi225220V50Hz: 1290 m3/h; 60Hz: 1450 m3/h50Hz: 2650 rpm; 60Hz: 2950 rpm50Hz: 70.5 dB(A); 60Hz: 73 dB(A)
SG225FLW-23Tphi225220V50Hz: 1070 m3/h; 60Hz: 1200 m3/h50Hz: 2700 rpm; 60Hz: 3030 rpm50Hz: 70 dB(A); 60Hz: 73 dB(A)
SG250FLW-23Tphi250230V1660 m3/h2650 rpm75 dB(A)
SG280FLW-23Tphi280230V2165 m3/h2710 rpm80 dB(A)
SG315FLW-23Tphi315230V50Hz: 2020 m3/h; 60Hz: 2275 m3/h50Hz: 1380 rpm; 60Hz: 1580 rpm50Hz: 63 dB(A); 60Hz: 65 dB(A)
SG315FLW-38Tphi3153-phase 380V50Hz: 2060 m3/h; 60Hz: 2330 m3/h50Hz: 1390 rpm; 60Hz: 1570 rpm50Hz: 63 dB(A); 60Hz: 65 dB(A)
SG355FLW-23Tphi355230V2585 m3/h1380 rpm63 dB(A)
SG355FLW-38Tphi3553-phase 380V50Hz: 2585 m3/h; 60Hz: 2955 m3/h50Hz: 1410 rpm; 60Hz: 1615 rpm50Hz: 63 dB(A); 60Hz: 65 dB(A)
16models
25spec categories
Modelcompare first
RFQnext

Model range at a glance

Compare available models by voltage, output, airflow, dimensions and application notes, then send the exact model and project conditions for quotation.

16models
25spec categories
Quotedetails
Docsrequest

Voltage

230V220V3-phase 380V

Power

50Hz: 29.6W; 60Hz: 30.1W50Hz: 50W; 60Hz: 50W50Hz: 53W; 60Hz: 57W50Hz: 68W; 60Hz: 75W50Hz: 69W; 60Hz: 85W50Hz: 86.5W; 60Hz: 110W

Airflow

50Hz: 238 m3/h; 60Hz: 277 m3/h50Hz: 465 m3/h; 60Hz: 540 m3/h50Hz: 455 m3/h; 60Hz: 520 m3/h50Hz: 560 m3/h; 60Hz: 630 m3/h50Hz: 620 m3/h; 60Hz: 745 m3/h50Hz: 970 m3/h; 60Hz: 1075 m3/h

Dimensions

phi133phi175phi180phi190phi220phi225

IP / environment

-25C to +60C50Hz: -25C to +60C; 60Hz: -25C to +50C-25C to +50C-25C to +40C

Applications

cabinet cooling; industrial equipment ventilation; equipment air movement

Best-fit buying situations

pressure-sensitive airflowequipment ventilationcabinet exhaust pathindustrial machinery

Series Quote details

model familyvoltageairflow targetpressure targetmounting directiontemperature conditionquantity

Purchasing notes

  • Vortex fans should not be selected only by nominal airflow.
  • Clarify suffix meanings and voltage variants.
  • Confirm test condition for airflow and pressure values.

Documents to request

datasheetperformance curvedimension drawingcertificate coverage

Next step

Use a selection path if cabinet conditions are unclear, or send the RFQ when model family, quantity and files are ready.

Move from product review to a quote request

Use the path that matches the information you already have.