Product page

SG250HA2(W)

Prepare an RFQ or document request for SG250HA2(W). Use the product details below to compare the model and prepare questions for the supplier.

Send model, quantity, cabinet conditions and required documents before ordering.
AC Axial Fans product reference

Use this product page to start a quotation

Collect cabinet conditions, voltage, quantity and required files. These model details help start the request and make the supplier reply more precise.

Key specifications

Use these product details to compare models, then request the latest datasheet, drawing, certificate coverage and availability before ordering.

220V / 50/60Hz Voltage / freq
85W at 50Hz; 110W at 60Hz / 0.41A at 50Hz; 0.5A at 60Hz Power / current
1350 m3/h at 50Hz; 1460 m3/h at 60Hz / P-Q curve to request Airflow / pressure
250mm round guard; front guard width 320mm available Size / cutout
round guard / cabinet ventilation; drawing dimensions require review / TOP wired internally; CCW seen on the leads Mounting / wiring

Product details

220V50/60Hz85W at 50Hz; 110W at 60Hz1350 m3/h at 50Hz; 1460 m3/h at 60HzP-Q curve to request60 dB(A) at 50Hz; 63 dB(A) at 60Hz2620 rpm at 50Hz; 2875 rpm at 60HzIP44

Request before ordering

required certificate or market documentson page; required certificate or market documentssample quantity and order quantity

SG250HA2(W) model sheet and drawing references

Model inquiry sheet for preparing the request. Ask for current documents before order.

Model sheet

Voltage / frequency220V / 50/60Hz
Power / current85W at 50Hz; 110W at 60Hz / 0.41A at 50Hz; 0.5A at 60Hz
Airflow1350 m3/h at 50Hz; 1460 m3/h at 60Hz
Noise / speed60 dB(A) at 50Hz; 63 dB(A) at 60Hz / 2620 rpm at 50Hz; 2875 rpm at 60Hz
IP / temperatureIP44 / -25C to +60C
Guard / dimensions250mm round guard; front guard width 320mm available
Mounting / airflowround guard / cabinet ventilation; drawing dimensions require review / TOP wired internally; CCW seen on the leads
Material / bearingsheet steel impeller coated black / maintenance-free ball bearings
Related itemsfan guard; filter; thermostat

Drawing references

SG250HA2(W) performance curve reference
Performance curve reference
SG250HA2(W) round guard product view reference
Round guard view reference
SG250HA2(W) side airflow dimensions drawing reference
Side airflow dimensions reference
SG250HA2(W) front guard dimensions drawing reference
Front guard dimensions reference
Front guard 320 mm front guard reference
Side reference 75 mm + 20 mm depth references; Ø250 / Ø275 +5/0 visible
Airflow 1350 / 1460 m3/h at 50 / 60 Hz
Speed 2620 / 2875 r/min at 50 / 60 Hz

Use these references to prepare the request; ask for the current drawing, curve file and certificate scope before ordering.

Before quotation

  • Match the old fan label, round guard diameter, airflow direction and mounting constraints before replacement quotation.
  • Request the current dimensional drawing and P-Q curve file before final panel or airflow decisions.
  • Confirm active export status, order-code meaning and certificate scope by exact model before ordering.

Model details

Product familyAC Axial Fans
Product typeaxial fan
Voltage220V
Frequency50/60Hz
Power85W at 50Hz; 110W at 60Hz
Current0.41A at 50Hz; 0.5A at 60Hz
Airflow1350 m3/h at 50Hz; 1460 m3/h at 60Hz
Static pressureP-Q curve to request
Noise60 dB(A) at 50Hz; 63 dB(A) at 60Hz
Speed2620 rpm at 50Hz; 2875 rpm at 60Hz
IP ratingIP44
Dimensions250mm round guard; front guard width 320mm available
Mountinground guard / cabinet ventilation; drawing dimensions require review
WiringTOP wired internally; CCW seen on the leads

Quote details

exact model and quantitycurrent datasheet and drawing needrequired certificate or market documentstarget market and applicationold model photo and replacement constraints

If this is a replacement inquiry, include old label photos, front grille size, cutout size, voltage and required fit tolerance.

SG250HA2(W) AC axial fan quote details

Use this section to organize replacement details, quote requirements and document requests before contacting the supplier.

  • AC axial fan sourcing where frame size, voltage, wiring, airflow and bearing option must be checked together.
  • Equipment ventilation replacement where the old fan code may not fully describe performance or connector details.
  • OEM batch requests that need sample quantity, annual usage and approval documents kept separate.

Replacement and RFQ inputs

frame size and thicknessold label photovoltage and frequencybearing and wiring preferenceairflow and noise target

These inputs help separate a fit-check, a new cabinet design, a distributor quote and a document request.

Details to ask before quote

  • Confirm order-code meaning, bearing option and wiring style.
  • Request dimension drawing, airflow/noise test condition and performance curve where available.
  • Confirm certificate coverage by model or approved series.

Can the frame size alone decide the fan?

No. Voltage, frequency, bearing, wiring and airflow conditions are needed before replacement.

What does a sample request need?

Add sample quantity, expected first batch, target approval documents and the machine or cabinet use case.

Can catalog airflow be compared directly?

Only after test condition and voltage are confirmed. Treat catalog values as inquiry inputs until reviewed.

Related model request pages

Documents to request before ordering

  • Current model name and export status.
  • Datasheet, dimension drawing, wiring or cutout drawing where relevant.
  • Certificate coverage by model or approved series coverage.
  • MOQ, sample availability, lead time and private-label limits.